NX
System and controller features | |
---|---|
Chassis | Compact 2U or 4U steel and aluminum alloy enclosure with rack mount kit, dual FRU power supplies and fan assemblies and 12 Gb/s drive backplane power on/off switch; system reset switch; LAN, fan fail, power indicators; six high-speed fans |
Controllers | 3.5 GHz Intel 1600 CPU, 12 bay 64GB (4x16), 24 bay 64GB (2x32) 36 bay 128GB (4x32) RAM |
Drive Support | 12/24/36 3.5” x SAS/SATA 12 Gb/s hard drives in field replaceable canisters staggered physical drive spin-up, drive LED support |
External I/O Ports | Four, 1 GigE host ports and SAS expansion on RAID card allows JBOD add-on capacities up to 72 drives for 12 bay and 144 drives on 24 / 36 bay |
Operational Features | |
---|---|
RAID protection | RAID 0,1,6 RAID 6 default. physical drive error recovery. Replacement drive rebuild and monitoring, SMART, error recovery mechanisms |
Spare Drives | Genesis NX RAID 6 configuration can be configured with or without a hot spare drive. RAID 6 has two parity drives and therefore doesn’t require a hot spare drive, however a hot spare can be configured at the factory by request. |
Key Features | Snapshots (VSS based) for file and block data: replication: global namespace: up to 240TB per share point file server resource management for quotas, file screening, storage utilization reports: indexing services for optimized search, built-in anti virus, built-in network backup clients. ADS & NIS User Group ID Synchronization NAS support for up to 240TB logical volumes. Multiple logical volume & groups, online logical volume expansion. |
Network Protocols | SMB, NFS, FTP, HTTP |
System Management | |
---|---|
Supported OS | Windows, macOS, Linux |
Management Tools | Embedded web management support — no host agent is needed using standard TCPIP; simple process to create users and groups, ADS synchronization volume creation or partitioning; NAS tuning tools for optimal performance for various applications;easy-to-parse error logs and status monitoring. |
Management Interfaces | Embedded web server and management support — no host agent is needed; Ethernet |
Event Notification | Email, audible (buzzer), and visible (LEDs) alerts for bad drives and power supplies |
Mechanical Specifications | |
---|---|
Voltage | 90-264 VAC Auto-Ranging 50-60 Hz |
Power Supply | 12 / 24 Bay: 920W Redundant PS; 36 Bay: 1280W Redundant PS |
Power Consumption | 12 Bay: 325 Watts; 24 Bay: 465 Watts; 36 Bay: 525 Watts |
Heat output | BTU per hour at 120VAC - 12 Bay: 1200; 24 Bay: 1700; 36 Bay: 2400 |
Operating Temperature | Operational 5°- 35°C (non operational -40° +70°C) |
Relative Humidity | 0-90% |
Chassis Dimensions | 12 Bay - width 17.2” (437mm) height 3.5” (89mm) depth 25.5” (648mm) |
24 Bay - width 17.2” (437mm) height 7” (178mm) depth 26” (660mm) | |
36 Bay - width 17.2” (437mm) height 7” (178mm) depth 27.5” (699mm) | |
Weight | 12 bay gross weight: 61 lbs (27.7 kg); 24 bay gross weight: 82 lbs (37.2 kg); 36 bay gross weight: 100 lbs (45.4 kg) |
Shipping Dimensions | 12 Bay - width 35” (889mm) height 8” (203.2mm) depth 24” (609.6mm) |
24 Bay - width 38” (965.2mm) height 14” (355.6mm) depth 26” (660.4mm) | |
36 Bay - width 39” (965.2mm) height 14” (355.6mm) depth 26” (660.4mm) |